Affiliated Companies: Excel Industries, Inc. and H.K. Holdings, Inc.

Bag House, BHA Dust Systems

Ref # 11111

YEAR: 1990


Year of Project: 1990
MFR Industrial Controls (Electrical)
Bag house approximately: 120 CFM.
Filter Area: 28,907 sq. ft.
Air to Cloth Ratio: 4.15 to 1
Temperature Operating: Less than 200 degree F
Design Pressure: +/- 20 Inches Water Column
Compressed Air Requirements (Normal 22 SCFM with a Maximum 55 SCFM):
@ 90 - 100 PSIG, Dry, Oil Free

Consisting of the following:

-Two (2) New York Blowers with 250 HP, 1785 RPM, AC motors
rated at 60 CFM ea. with a 48" Fan Inlet.
-Two (2) spare New York Blowers w/ motors complete available.
-One (1) Drop Out Box
-One (1) Baghouse consisting of eight (8) compartments
-Total number of bags: 1768, size of bag 6.25" OD x 120" Long
-Duct work from both EM-1 & EM-2
-One (1) stack 90'-0" tall
-One (1) Control House from EM-1 & One (1) Control House from EM-2 available
-Cages for bags collected from EM-1 & EM-2 in storage (Shipping Container)
-Cage size: 5.850" x 119.5" long
-Dust Augers, Drives, Motors & and other components from both EM-1 & EM-2
in storage (Shipping Container)
-Drawings & additional information available upon request, to include photos

Your machine has been added to the Cart.

Click the Checkout button below or continue adding machines to the Cart.

1

Main Office  |  723 Phillips Avenue, Bldg. D2 Toledo, Ohio 43612  |  Phone: (419) 841-3586  |  Fax: (419) 841-2986  |  Email: sales@dnhmachinery.com